{"id":1158,"date":"2012-10-26T11:26:01","date_gmt":"2012-10-26T10:26:01","guid":{"rendered":"http:\/\/www.crimsoniv.co.uk\/beta\/?page_id=1158"},"modified":"2016-11-03T14:32:15","modified_gmt":"2016-11-03T14:32:15","slug":"infrared-windows-buy-here","status":"publish","type":"page","link":"https:\/\/www.crimsoniv.co.uk\/beta\/infrared-windows-buy-here\/","title":{"rendered":"Infrared Windows &#8211; Buy here."},"content":{"rendered":"<p>Buy your industrial Infrared Windows from Crimson Industrial Vision.<\/p>\n<h2>Why use an Infrared Window?<\/h2>\n<ul>\n<li>Reduces risk of arc flash<a href=\"https:\/\/www.crimsoniv.co.uk\/beta\/wp-content\/uploads\/2012\/10\/QuadraFNX_112.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"alignright size-thumbnail wp-image-1134\" title=\"Infrared Window Inspection\" src=\"https:\/\/www.crimsoniv.co.uk\/beta\/wp-content\/uploads\/2012\/10\/QuadraFNX_112-150x150.jpg\" alt=\"IR Window Inspection\" width=\"150\" height=\"150\" srcset=\"https:\/\/www.crimsoniv.co.uk\/beta\/wp-content\/uploads\/2012\/10\/QuadraFNX_112-150x150.jpg 150w, https:\/\/www.crimsoniv.co.uk\/beta\/wp-content\/uploads\/2012\/10\/QuadraFNX_112-36x36.jpg 36w, https:\/\/www.crimsoniv.co.uk\/beta\/wp-content\/uploads\/2012\/10\/QuadraFNX_112-115x115.jpg 115w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/a><\/li>\n<li>Increases equipment reliability<\/li>\n<li>Reduces need for additional manpower support during regular inspections<\/li>\n<li>Allows rapid view of what&#8217;s really happening to key components for ad hoc inspections<\/li>\n<li>Easy to install<\/li>\n<\/ul>\n<div><\/div>\n<div>To read more about the use of infrared windows read <strong><span style=\"text-decoration: underline;\"><span style=\"color: #000080;\"><a title=\"Infrared windows lead to better inspections\" href=\"http:\/\/www.engineeringmaintenance.info\/editorial\/magazine-features\/11504-infrared-windows-lead-to-better-inspections\"><span style=\"color: #000080; text-decoration: underline;\">our article in EMS Magazine<\/span><\/a><\/span><\/span><\/strong><\/div>\n<p>The FLIR IRW series of Infrared windows are available in 3 standard sizes:<\/p>\n<table id=\"tablepress-3\" class=\"tablepress tablepress-id-3\">\n<thead>\n<tr class=\"row-1 odd\">\n<th class=\"column-1\"><a href=\"http:\/\/crimsoniv.co.uk\/wp-content\/uploads\/2012\/10\/FLIR-Infrared-Window.png\"><img src=\"http:\/\/crimsoniv.co.uk\/wp-content\/uploads\/2012\/10\/FLIR-Infrared-Window-150x150.png\" alt=\"FLIR Infrared Window\" title=\"FLIR Infrared Window\" width=\"150\" height=\"150\" class=\"alignright size-thumbnail wp-image-1136\" \/><\/a><\/th>\n<th class=\"column-2\">2&#8243; Infrared Window<br \/>\n(IRW-2C)<\/th>\n<th class=\"column-3\">3&#8243; Infrared Window<br \/>\n(IRW-3C)<\/th>\n<th class=\"column-4\">4&#8243; Infrared Window<br \/>\n(IRW-4C)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"row-2 even\">\n<td class=\"column-1\"><\/td>\n<td class=\"column-2\"><\/td>\n<td class=\"column-3\"><\/td>\n<td class=\"column-4\"><\/td>\n<\/tr>\n<tr class=\"row-3 odd\">\n<td class=\"column-1\">Overall Height\n<\/td>\n<td class=\"column-2\">85.5mm<\/td>\n<td class=\"column-3\">107.4mm<\/td>\n<td class=\"column-4\">136.5mm<\/td>\n<\/tr>\n<tr class=\"row-4 even\">\n<td class=\"column-1\">Overall Width<\/td>\n<td class=\"column-2\">73mm<\/td>\n<td class=\"column-3\">99mm<\/td>\n<td class=\"column-4\">127mm<\/td>\n<\/tr>\n<tr class=\"row-5 odd\">\n<td class=\"column-1\">Overall Thickness<\/td>\n<td class=\"column-2\">25.5mm<\/td>\n<td class=\"column-3\">26.86mm<\/td>\n<td class=\"column-4\">29.25mm<\/td>\n<\/tr>\n<tr class=\"row-6 even\">\n<td class=\"column-1\">Required Actual Hole Dia.<br \/>\n(Nominal)<\/td>\n<td class=\"column-2\">60.3mm<\/td>\n<td class=\"column-3\">88.9mm<\/td>\n<td class=\"column-4\">114.3mm<\/td>\n<\/tr>\n<tr class=\"row-7 odd\">\n<td class=\"column-1\">Recommended Max Panel Thickness<\/td>\n<td class=\"column-2\">3.2mm<\/td>\n<td class=\"column-3\">3.2mm<\/td>\n<td class=\"column-4\">3.2mm<\/td>\n<\/tr>\n<tr class=\"row-8 even\">\n<td class=\"column-1\">Optic Specifications<\/td>\n<td class=\"column-2\"><\/td>\n<td class=\"column-3\"><\/td>\n<td class=\"column-4\"><\/td>\n<\/tr>\n<tr class=\"row-9 odd\">\n<td class=\"column-1\">Optic Diameter<\/td>\n<td class=\"column-2\">50mm<\/td>\n<td class=\"column-3\">75mm<\/td>\n<td class=\"column-4\">95mm<\/td>\n<\/tr>\n<tr class=\"row-10 even\">\n<td class=\"column-1\">Viewing Aperture Diameter<\/td>\n<td class=\"column-2\">45mm<\/td>\n<td class=\"column-3\">69mm<\/td>\n<td class=\"column-4\">89mm<\/td>\n<\/tr>\n<tr class=\"row-11 odd\">\n<td class=\"column-1\">Viewing Aperture Area<\/td>\n<td class=\"column-2\">1590mmsq<\/td>\n<td class=\"column-3\">3739mmsq<\/td>\n<td class=\"column-4\">6221mmsq<\/td>\n<\/tr>\n<tr class=\"row-12 even\">\n<td class=\"column-1\">Ratings &amp; Testing<\/td>\n<td class=\"column-2\"><\/td>\n<td class=\"column-3\"><\/td>\n<td class=\"column-4\"><\/td>\n<\/tr>\n<tr class=\"row-13 odd\">\n<td class=\"column-1\">Optic Maximum Temperature<\/td>\n<td class=\"column-2\">1355.6 C<\/td>\n<td class=\"column-3\">1355.6 C<\/td>\n<td class=\"column-4\">1355.6 C<\/td>\n<\/tr>\n<tr class=\"row-14 even\">\n<td class=\"column-1\">Pull Out Strength<\/td>\n<td class=\"column-2\">657kg<\/td>\n<td class=\"column-3\">1655kg<\/td>\n<td class=\"column-4\">1678kg<\/td>\n<\/tr>\n<tr class=\"row-15 odd\">\n<td class=\"column-1\"><\/td>\n<td class=\"column-2\"><\/td>\n<td class=\"column-3\"><\/td>\n<td class=\"column-4\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><!-- #tablepress-3 from cache --><\/p>\n<p>For more information or to arrange a quotation <a href=\"mailto:info@crimsoniv.co.uk?subject=&quot;Infrared Windows - tell me more&quot;\"><span style=\"text-decoration: underline;\"><span style=\"color: #000080;\"><strong>click here<\/strong><\/span><\/span><\/a><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Buy your industrial Infrared Windows from Crimson Industrial Vision. Why use an Infrared Window? Reduces risk of arc flash Increases equipment reliability Reduces need for additional manpower support during regular inspections Allows rapid view of what&#8217;s really happening to key components for ad hoc inspections Easy to install To read more about the use of <a href=\"https:\/\/www.crimsoniv.co.uk\/beta\/infrared-windows-buy-here\/\" rel=\"nofollow\"><span class=\"sr-only\">Read more about Infrared Windows &#8211; Buy here.<\/span>[&hellip;]<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"open","template":"","meta":{"footnotes":""},"_links":{"self":[{"href":"https:\/\/www.crimsoniv.co.uk\/beta\/wp-json\/wp\/v2\/pages\/1158"}],"collection":[{"href":"https:\/\/www.crimsoniv.co.uk\/beta\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.crimsoniv.co.uk\/beta\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.crimsoniv.co.uk\/beta\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.crimsoniv.co.uk\/beta\/wp-json\/wp\/v2\/comments?post=1158"}],"version-history":[{"count":9,"href":"https:\/\/www.crimsoniv.co.uk\/beta\/wp-json\/wp\/v2\/pages\/1158\/revisions"}],"predecessor-version":[{"id":1166,"href":"https:\/\/www.crimsoniv.co.uk\/beta\/wp-json\/wp\/v2\/pages\/1158\/revisions\/1166"}],"wp:attachment":[{"href":"https:\/\/www.crimsoniv.co.uk\/beta\/wp-json\/wp\/v2\/media?parent=1158"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}